4 key steps to overcome material surface defects
Dec 08, 2021
Leave a message
What does "defect free" really mean?
A fundamental problem arises when an engineering drawing states "No defects", "no residues", "no oil, grease and particles", "no crumbs", "no scratches" or otherwise indicates that a material surface defect is unacceptable. Drawings are often marked with features such as "no drawing lines", "no gouging" and "no longitudinal die lines".
The problem with these requests is, when you look at the surface of the part, what does this actually mean?
If you look carefully at any surface, you will find defects. (Ever look at your skin in a regular mirror, then look at your skin in a 10x magnifying glass? This is true of even the most precise metal work.
Differences at the micro level
From a microscopic point of view, the surface may have lines that are not visible at 10x magnification, but look like major valleys when examined under 50x magnification. The surface of the cutting tube may look uniform at 10 x magnification, but defects in grain arrangement will be revealed using scanning electron microscopy (SEM) at 500 x magnification.
At very high magnification, almost every material has surface problems. However, when a surface is required to be "defect-free", drawings often fail to specify how carefully the surface of a part should be inspected or, more importantly, how carefully it will be inspected by the customer.
So, how to overcome the problem of material surface defects? Apply these four steps!
1. Determine magnification
In order to ensure that parts are inspected to the appropriate level of detail, it is important to determine the magnification of the material surface that needs to be checked. Magnification is the ratio between an object's apparent size (or its size in an image) and its actual size, expressed as 5x, 10x, 20x, 50x, etc.
By indicating the magnification rate on the drawing, you and your supplier will obtain an agreed level that can be used to measure whether the material's surface meets your needs.
But what should be considered when specifying magnification?
When selecting the magnification level, it is also important that it is meaningful for end use. Since a closer inspection adds to the cost, you need to ensure that you do not over-engineer parts and require surface finishes that exceed your requirements, which may exceed your budget.
For example, it may be excessive to check the part at 100 magnification if slight grooves in the pipe or rod do not affect the performance of the part. However, if you are producing ball bearings that will be used in critical aircraft parts, high magnification levels may be required to ensure functionality and meet safety requirements.
Consider the Angle of the light source
Keep in mind that the Angle of the light source also affects the appearance of the material surface on a microscopic level.
The Angle of the light can cause shadows and reflections that can increase or decrease the perceived size of drawing lines, cracks, grooves, dents, and other surface finish defects. The Angle can also change the appearance or hide the presence of discoloration.
Light microscopes can rely on a variety of light sources, such as circular lamps, embedded fiber optics, parallel fluorescent tubes, and even backlit lamps - all of which cast different shadows.
3. Identify the color temperature of light
Another variable is the color temperature of the light, which is a more holistic way of looking at the light source rather than just identifying whether the microscope uses LED, fluorescent or incandescent lighting.
This property of visible light is represented by kelvin (K). Temperatures above 5,000 K are called cool colors (blue-white) and lower temperatures (2,700-3,000 K) are called warm colors (yellow-white to red).
The difference in color temperature will affect the appearance of the surface of the parts. This may lead to inconsistencies in:
How can two people look at the same part in different light, how can they see and describe the material surface
In a shared photo or video, the appearance of a surface whose explicit purpose is to confirm how the part "should look"
Consider the presence of light
However, another variable to consider is that there is no light at all - or, more specifically, no light as in the case of SEM.
All microscopy involves looking at objects and/or areas of their surface that are not visible to the naked eye. Light microscopes use diffraction, reflection, or refraction of visible light beams to create images.
However, SEM examines a sample by scanning it with a focused electron beam that is reflected from the sample's topography to produce a three-dimensional image of the object and/or surface. In other words, to the human eye, SEM observes parts in complete and total darkness!
This means no confusing shadow effects.
Is SEM suitable for your application?
Because the wavelength of electrons is much smaller than that of visible light, SEM is able to produce much greater detail at a much higher resolution than that produced by an optical microscope. In addition, SEM has a larger focal depth and therefore more detailed 3D imaging.
However, SEM has major disadvantages, including the electron source, the lens and the sample must all be in a vacuum. SEM is also very expensive, complex and difficult to use for everyday applications.
In addition, because SEM is fundamentally different from ordinary microscopy methods, SEM cannot be compared with what the eye sees using more typical light microscopy methods. Thus, while the level of detail generated by SEM is astounding, it is incompatible with typical resources in a factory or store.
This means that requiring SEM level "defect free" is unrealistic, at least for now.
Thinking about it now helps ensure quality later
The good news is that you can and should always specify magnification levels for part surfaces using more typical microscopy methods.
Ordinary light microscopes can measure anywhere from 5x to 50x, and there are other more advanced options. For example, Metal Cut Corporation has an optical microscope capable of magnification up to 200 times, and our video inspection equipment can display a higher level of detail.
Most importantly, consider material surfaces, magnification and how they relate to end-use requirements early in the manufacturing process -- for example, when you make drawings or complete RFQS. This not only helps you avoid problems, but also helps ensure that your parts pass inspection and meet your needs.
Please contact us at zhang@pride-cnc.com